(Vertical) Beam Size Measurements at ANKA

16 Jun 2015, 09:00
15m
Marie Curie Room (ALBA Synchrotron)

Marie Curie Room

ALBA Synchrotron

Ctra. BP 1413 km. 3,3 Cerdanyola del Vallès

Speaker

Nicole Hiller (KIT)

Description

For transverse beam size measurements we have the following diagnostics devices at hand at ANKA: - Synchrotron light monitor (can resolve the horizontal beam size nicely, but not the vertical beam size) - Double-Slit Interferometer (can resolve the vertical beam size nicely) - DIAX (can resolve the vertical beam size nicely, but only above 2.3 GeV) - Fast-Gated Intensified Camera with a flipping mirror (can resolve the horizontal beam size with single-shot measurements even in a multi-bunch environment